Datafill Sequence And Implications; Datafill; Table 22 Field Descriptions For Table Ipthron For Eiu Datafill - Nortel DMS-100 User Manual

Nortel ethernet interface unit user guide
Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

For more information on throttling, refer to"IP throttling" on page 61 and to
the Provisioning Rules for LPP, SSLPP, and SNSE LIS, System Engineering
Bulletin number 92-02-001, version 01.09.
Datafill sequence and implications
The following tables must be datafilled before table IPTHRON:
Datafill
Table 22 on page 91 lists the fields and value ranges used to datafill an EIU in
table IPHOST.
While table 22 provides all the information you need to datafill for EIUs,
complete information on table IPHOST is in DMS-100 Translations Guide,
297-xxxx-350.

Table 22 Field descriptions for table IPTHRON for EIU datafill

Field
Subfield or
refinement
LMSNODE
LIUNAME
LIUNO
TXCAPCT
RXCAPCT
(Sheet 1 of 3)
inventory tables for nodes that are datafilled in field SNNODE in table
IPTHRON
Entry
see subfields
APU
or
EIU
0 to 750
0 to 32767
0 to 32767
Explanation and action
Local message switch node
This is the first and key field of the table
and consists of subfields LIUNAME and
LIUNO.
Link interface unit name
Enter the link interface unit (LIU) name.
This field indicates an IP capable node
connected to the local message switch.
The node datafilled here must first be
datafilled in table LIUINV.
Enter APU for application processor
unit.
Enter EIU for Ethernet interface unit.
Link interface unit number
Enter the node index.
Transmit capacity
Enter the IP transmission rate in kbyte/s
from the node to all other SuperNode IP
nodes.
Receive capacity
Enter the IP receive rate in kbyte/s from
all other SuperNode nodes to the node.
DMS-100 Family EIU User Guide TELECOM12
Chapter 3: EIU datafill 91

Hide quick links: