Communications
10.2 Acyclic data exchange
Note
When a dataset 100 is written, it is no longer possible to use the datasets for field type 2.
Dataset 101 to 132 "field type 2"
Byte
0,1
1,2
...
44,45
46,47
Using these datasets, fields of type 2 can be defined. This field type comprises channels that
are directly assigned.
Application range: Blow-molding, forming a layer over all POMs (e.g. every first channel of a
POM).
Definition is performed directly via the type "Word". Up to 24 channels can be defined.
The field number corresponds to the dataset number minus 100.
Field number 0 cannot be used. It exists automatically in the HCS and contains all the
channels of the HCS by default. Production and standby setpoints are preset to 100 %.
All channels that are not explicitly assigned to a new field remain in this default field. To use
fields, the user must ensure that all the existing channels are assigned to a user field.
A field can be erased by entering a 0 for all channels ("0" refers to the dataset length).
Note
When one of the datasets 101 to 132 is written, it is no longer possible to use the dataset for
field type 1.
88
Description
Number of channel 1 of field (dataset number minus 100)
Number of channel 2 of field (dataset number minus 100)
...
Number of channel 23 of field (dataset number minus 100)
Number of channel 24 of field (dataset number minus 100)
Operating Instructions, 11/2015, A5E35452705A/002
SIPLUS HCS4300