Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Pressure Regulator Removal

Condition Requirements:
Main Top Removed
Gas Supply Disconnected
Gas leak hazard. To avoid risk of personal injury
or death, leak testing of the appliance must
be conducted according to the manufacturer's
instructions. Before placing appliance in operation,
always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
1. Remove screw that secures manifold assembly to
range.
2. Remove screw and cover from range.
3. Remove pressure regulator from manifold.
4. Reverse procedure for installation.
Note: Use approved sealant when installing pressure
regulator.
5. Perform gas leak test.