Led Error Codes; Thermostat Control Connections; Quick Power Disconnect; Oven Components - Viking DCCG130 Service Manual

30 inch
Table of Contents

Advertisement

Troubleshooting
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

LED Error Codes

The LED error codes are displayed on the control
panel using the cycle lights. Refer to the chart below to
determine the type of error that is being displayed.
LED Error Codes
Type of error
RTD
2 fl ashes, then 4 seconds OFF
(Oven Probe)
Model Header
3 fl ashes, then 4 seconds OFF

Thermostat Control Connections

(Part may vary)

Oven Components

Symptom
Bake, broil, convection fan, oven
lights, and surface burner igniters
inoperable
Bake, broil inoperable - convection
fan, oven lights, and surface burner
igniters operate
12
Cycle Light
Possible Cause
House breaker or fuse open
Unit unplugged
Defective oven wiring (shorted,
open, or burned)
Defective oven wiring (shorted,
open, or burned)
Open or shorted RTD (cycle light
fl ashing)
Open oven control
Open direct spark module
Defective oven wiring (shorted,
open, or burned)

Quick Power Disconnect

The DCCG130 range has a quick power disconnect
located behind the kick plate. Use this disconnect
location instead of pulling the range from the installation
and unplugging from the outlet.
1. Remove screws and lift kick plate from keyhole
screws.
2. Disconnect Molex connector to remove power to the
range.
3. Reverse procedure for installation.
Reset breaker or replace fuse
Plug in unit
Replace high limit
Repair or replace defective wiring
Replace RTD
Replace oven control
Replace direct spark module
Repair or replace defective wiring
Corrective Action
©2010 Viking Preferred Service