Step 13. HOOD INSTALLATION

Refer to Figure 61. All of these appliances must have hoods installed
prior to operating.
On all clean face units, slide the hood into the slots on the lower edge of the
radiant panel (Figure 61).

FINISHING REQUIREMENTS

- Wall Details
Complete finished interior wall. To install the appliance facing flush with
the finished wall, position framework to accommodate the thickness of the
finished wall (Figure 61)
See Page 7 for Cold Climate Insulation and Page 10 for
Clearances
Combustible
Finished Wall
Materials
Combustible
materials
NOT allowed
below this point
on face
of appliance.
4" Header
Spacing
Top Standoff
Hood must be installed as shown.
Figure 61
NOTE:
• If the barrier becomes damaged, the barrier shall
be replaced with the manufacturer's barrier for this
appliance.
• For use with barrier(s) Part No(s). J7420 (40" Models)
and J7428 (45" Models).
NOTICE: All DRT4000 model fire-
places include barriers to reduce the
risk of burns from hot viewing glass.
The barriers in the fireplace are
screens shown right.
J7420 (40" Models)
J7428 (45" Models)
Figure 62
This area must remain
clear of combustible
materials.
Min. 1"
(25mm)
This area must
remain clear of
combustible
materials.
Top of Appliance
Top of Door Fram
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INSTALLATION ACCESSORIES
Listed Secure Vent
Cat. No.
H1968
H2152
Vent Sections
77L70
(Rigid)
77L71
77L72
77L73
77L74
77L75
77L76
77L77
The following flashings come packaged with a storm collar:
77L78
77L79
77L80
77L81
H6183
H6184
H2246
H2247
96K92
Any safety screen, guard, or
barrier removed for servicing
an appliance must be replaced
prior to operating the appliance.
Installation and Operation Instructions
900357-00, 09/2015
Components
®
Model
Description
SV4.5HT-2
Horizontal Square Termina-
tion With Firestop / spacer
(H2246) & Adaptor (74L61)
SV4.5CGV-1
Vertical Termination Cap,
High Wind
SV4.5L6
6" (152 mm)
SV4.5L12
12" (305 mm)
SV4.5L24
24" (610 mm)
SV4.5L36
36" (914 mm)
SV4.5L48
48" (1219 mm)
SV4.5LA
Telescopic Length Slip Sec-
tion (2" to 7-1/2" rigid)
SV4.5E45
45 Degree Elbow
SV4.5E90
90 Degree Elbow
SV4.5F
Flat Roof Flashing
SV4.5FA
1/12 to 7/12 Adjustable
Flashing
SV4.5FB
7/12 to 12/12 Adjustable
Flashing
SV4.5SC6
Storm Collar (6 per box)
SV4.5HF5
Firestop Spacer, 5", rigid
SF4.5HF5
Firestop Spacer, 5", flex
SV4.5HF-10
Firestop / Spacer-Horizon-
tal, rigid (3-1-1 spacing),
10 Pack
SV4.5VF-10
Firestop / Spacer-Vertical,
rigid (1-1-1 spacing), 10
Pack
SV4.5SP
Support Plate
WARNING
35

Advertisement

Table of Contents
loading

Table of Contents