Step 12. Hood Installation; Finishing Requirements - Superior Fireplaces DRT35STDMN Installation And Operation Instruction Manual

See-through and peninsula direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRT35ST and DRT35PF Direct-Vent Gas Fireplaces
Decrease Shutter Opening
In This Direction
Orifice
Increase Shutter Opening
In This Direction
Air Shutter
Adjusting Rod
Note - Burners are omitted in this view for clarity.
Main Burner Factory Air Shutter
Opening Setting - All Models
Model
Natural
Gas
All Models
1/8"
3.2mm
Adjustment Rod Positions
Figure 64
(when viewed from above)

Step 12. HOOD INSTALLATION

Refer to Figure 65. All of these appliances
must have front face assemblies and barriers
and hoods installed prior to operating.

FINISHING REQUIREMENTS

Wall Details
Complete finished interior wall. To install the
appliance facing flush with the finished wall,
position framework to accommodate the thick-
ness of the finished wall (Figure 65).
See Page 7 for
Cold Climate Insulation and
Page 10 for Clearances
Propane
Front face assem-
Gas
bly and hood must
be installed as
1/4"
6.4mm
Figure 65 - FINISHING REQUIREMENTS
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Combustible
Wall
Framing
Combustible
Finished Wall
Materials
This Area Must Remain
Clear of Combustible
Materials
5" Top Standoff
Top of Appliance
Top of
Door Frame
shown.
Installation and Operation Instructions
900300-00, 01/2018
This Area Must Remain
3" (77 mm)
Clear of Combustible
Materials
1" Min.
(26 mm)
37