The indicator LED flashes in green when:
-
the remaining battery level is found to be 40% or above as a result of performing the battery level check (twice when
battery type is set to LR6 (AA) alkaline battery, once when battery type is set to rechargeable nickel hydride battery).
The indicator LED can be disabled with the QR-coded parameter menu or configuration software (Scan Tune App). In any of
the following cases, however, the indicator LED turns on regardless of the current LED setting:
-
when the scanner is being customized with the QR-coded parameter menu,
-
when the scanner receives an LED-ON command (LB, LG or LR) from the host computer (refer to Appendix 2),
-
when the configuration software (Scan Tune App) starts up or any setting is newly reflected,
-
when the scanner scans a batch-process QR Code symbol,
-
when the parameter values are saved by a PW command (refer to Appendix 2),
-
when the scanner failed to save parameter values specified with the configuration software (Scan Tune App), QR-coded
parameter menu, or control commands,
-
when a run-time error has occurred in ADF script,
-
when the trigger switch is pressed when the trigger switch control is disabled,
®
-
when the Bluetooth
-
when the battery voltage has dropped,
-
when the battery voltage status is displayed, or
-
when the scanner failed to save the settings.
wireless link status is displayed,