ELEVATION SERIES CIM CUBERS
Route the refrigerant lines through the roof opening. Follow straight line routing whenever possible. Any
excess tubing MUST remain inside the building. Spiral the excess length of pre-charged tubing inside the
building. Use a horizontal spiral to avoid any traps in the lines.
Have the roofing contractor seal the holes in the roof per local codes.
CAUTION: The couplings on the sets of pre-charged lines are self sealing when installed properly. Carefully
The following remote ice makers incorporate the Mixing Valve in the Condenser. This configuration
allows up to a 100 foot calculated remote line set run. Reference the diagram on the next page to calculate
the maximum 100 ft. line set run. Maximum actual line set run is limited to 75ft.
CIM Machine Model Number
CIM0530R
CIM0535R
CIM0636R
CIM0825R/0826R/0835R/0836R/0837R
CIM1125R/1126R/1135R/1136R/1137R
CIM1446R/1447R
CIM1545R/1845R
CIM2046R/2047R
Verify the CIM machine is compatible with the remote condenser.
For more information contact your Ice-O-Matic distributor.
follow the instructions in the Remote Condenser manual.
REMOTE CONDENSER GUIDELINES
Remote Condenser Model Number
VRC1001B/RCA1001
VRC1061B/RCA1061
VRC1061B/RCA1061
VRC2061B/RCA2061
VRC2061B/RCA2061
VRC2661/RCA3061
VRC2661/RCA3061
VRC5061B/RCA3561