ELEVATION SERIES CIM CUBER
CONTROL BOARD
Power and Clean LED Flash Description
SOLID - On Constantly
SLOW - Flashes once every second
QUICK - Flashes once every half second
DOUBLE SLOW - Flashes twice then 1 second delay
DELAYED - flashes once every 3 seconds
Error Codes
Error 1 - POWER LED QUICK FLASH RED - Unit has experienced a MAX Freeze (1 hr), MAX
Harvest (5.5 minutes) or BOTH.
Error 2 - POWER LED SLOW FLASH IN OFF STATE ONLY - Thermistor Failure.
Error 3 - POWER LED RED AND CLEAN LED YELLOW QUICK FLASH - Unit has experi-
enced a MAX Fill (5 min) or MAX Purge (2 min).
Minimum / Maximum Times
Freeze - 5 Minute Minimum / 1 Hour Maximum
Standard Harvest - 20 Second Minimum / 5.5 Minute Maximum
Water Fill - No Minimum / 5 Minute Maximum
Purge - 7 Second Minimum / 2 Minute Maximum