ELEVATION SERIES CIM CUBERS
= Illuminated LED
CONTROL BOARD - RETURN TO FREEZE
As the ice slab falls from the Evaporator, the Curtain(s) is pushed out and the contacts of the Curtain
Switch(s) open and close, terminating the Harvest Cycle. With a closed Curtain and Bin Thermostat (if
added), the unit will restart the Freeze Cycle. The Compressor (R2) and Fan(s) (R1) will continue opera‐
tion as the Water Inlet Valve (R4) is energized to fill the Sump until the High Water Float opens.