Recover the refrigerant from the unit. During the recovery disconnect curtain switch and push pad ribbon
and move the wiring clear of the area. Remove the two mounting screws in the base of the unit near the
curtain switch. Depending on the one being replaced remove the left or right side screws.
Curtain Switch
Ribbon
Mounting Screws
Right Side of Unit
Remove the splash curtain, evaporator cover, top evaporator cover, water distribution tube, water pump
tube and its connector, sump, water pump, and float switch housing assembly.
Left Side
Top cover
Evap. Cover
Curtain
Sump
Water
Pump
EVAPORATOR REPLACEMENT
Mounting Screws
Left Side of Unit
Right Side
Water
Distribution
Tubes
Float Switch
Housing
Water Pump Tube