ELEVATION SERIES CIM CUBERS
= Illuminated LED
CONTROL BOARD - HARVEST
After the Purge Valve and Water Pump de‐energize, the Water Inlet Valve will remain open for 20 sec‐
onds, partially filling the SUMP in preparation for the next Freeze Cycle (R2, R3, and R4, are illuminated
on Air and Water Cooled units, R1 is also energized on Remotes.) The Low Float Switch will go off as the
water level rises.
The Hot Gas Valve and Harvest Assist will remain energized for the remainder of the Harvest Cycle.
BLUE w/ WHITE
BLUE w/ RED
12V DC Switches
WHITE
WHITE
BLUE
R1
R2
R3
BLUE
BLACK
BROWN
VIOLET
RED
SEQUENCE OF OPERATIONS
R4
R5
R6
Line Voltage
TAN
YELLOW
PINK
Components
21