ELEVATION SERIES CIM CUBERS
= Illuminated LED
CONTROL BOARD - INITIATING HARVEST
When the water level in the SUMP drops to close the contacts of the Low Float Switch (LED on Board illu‐
minates) after a 5 second de‐bounce of the switch will signal the start of the Harvest Cycle.
BLUE w/ WHITE
BLUE w/ RED
12V DC Switches
WHITE
WHITE
BLUE
R1
R2
R3
R4
BLUE
BLACK
BROWN
VIOLET
RED
SEQUENCE OF OPERATIONS
R5
R6
Line Voltage
TAN
YELLOW
PINK
Components