ELEVATION SERIES CIM CUBERS
= Illuminated LED
CONTROL BOARD - COMPRESSOR START
The Compressor will be energized (R2 on Board illuminated) and the Hot Gas Valve will remain open for 5
more seconds and then de‐energize (R3 on Board off).
BLUE w/ WHITE
BLUE w/ RED
WHITE
WHITE
BLUE
R1
R2
R3
BLUE
BLACK
BROWN
VIOLET
RED
SEQUENCE OF OPERATIONS
12V DC Switches
R4
R5
R6
Line Voltage
TAN
YELLOW
PINK
Components
14