ELEVATION SERIES CIM CUBERS
= Illuminated LED
CONTROL BOARD - HARVEST
After the contacts of the Low Float Switch close, the Harvest Cycle starts by energizing the Hot Gas Valve,
Harvest Assist, Purge Valve AND Water Inlet Valve (R2, R3, R4, R5 and R6 are illuminated on Air and
Water Cooled units, ALL Relays are energized on Remotes.) The Purge Valve will close after 7 sec‐
onds.(Default Setting)
NOTE: Minimum harvest time is 20 seconds. Maximum harvest time is 5.5 minutes.