ELEVATION SERIES CIM CUBER
WATER PUMP
Water Pump Removal
The "foot" of the Water Pump points towards the right front corner of the unit. Grasp the foot
and turn counter clockwise. When the foot points towards the right rear corner, you will feel the
weight of the pump as the collar clears the base connections. Lower the Water Pump and dis‐
connect. Re‐install the Water Pump by first making the electrical connection, the push Pump up
pointing the Foot at the right rear corner and turn clockwise to secure.