Calculate The Total Piping Length - Daikin Altherma R Hybrid Installer's Reference Manual

Hide thumbs Also See for Altherma R Hybrid:
Table of Contents

Advertisement

7.12.3 Calculate the total piping length

CHYHBH05+08AF + EHYKOMB33A
Daikin Altherma R Hybrid
4P471761-1E – 2020.10
INFORMATION
Carefully follow the instructions as described in the adapter set.
When the resistance of the flue pipe and air supply pipe increase, the appliance
power will decrease. The maximum permitted reduction in power is 5%.
The resistance of the air supply pipe and combustion gas flue depends on:
the length,
the diameter,
all components (bends, elbows,...).
The total permitted pipe length of the air supply and the combustion gas flue is
indicated for each appliance category.
Equivalent length for concentric installation (60/100)
Bend 90°
Bend 45°
Equivalent length for dual pipe installation
R/D=1
R/D=0.5
Length (m)
1.5
1
Bend 90°
Bend 45°
Elbow 90°
Elbow 45°
7
Installation
|
Length (m)
2 m
1 m
4 m
2 m
Installer reference guide
89

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents