Explanation of the flue systems
Category in accordance with CE
C
Horizontal flue system. Discharge in the outside
13
wall. Inlet opening for the air supply is in the
same pressure zone as the discharge.
C
Vertical flue system. Flue gas discharge via the
33
roof. Inlet opening for the air supply is in the
same pressure zone as the discharge.
C
Joint air supply and flue gas discharge duct (CLV
43
system). Twin pipe or concentric.
C
Separate air supply and separate flue gas
53
discharge duct. Discharge into different pressure
zones.
C
Free in the market available flue material with CE
63
approval.
C
Joint air supply and flue gas discharge duct (CLV
83
system). Discharging into different pressure
zones.
C
Air supply and flue gas discharge duct in shaft or
93
ducted: concentric. Air supply from existing duct.
Flue gas discharge via the roof. Air supply and
flue gas discharge are in the same pressure zone.
CHYHBH05+08AF + EHYKOMB33A
Daikin Altherma R Hybrid
4P471761-1E – 2020.10
Single boiler installation
Please note that NOT all flue gas configurations as described below are allowed in
all countries. Please follow the local and national regulations.
INFORMATION
All piping lengths in the tables below are maximum equivalent piping lengths.
L1
C
13
1
INFORMATION
The above installation examples are just examples and can differ on some details.
L1
C
53
3
C
33
2
L1
C
93
4
For example: a wall terminal through the façade.
For example: a vertical roof terminal.
Do NOT mix flue materials from different
suppliers.
Only as twin pipe system.
Concentric flue system between the gas boiler
and the duct.
7
Installation
|