Calculate The Total Piping Length - Daikin Altherma EHYHBH05A Series Installer's Reference Manual

Hybrid heat pump
Table of Contents

Advertisement

7.6.3 Calculate the total piping length

EVLQ05+08CA + EHYHBH05A + EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
INFORMATION
Carefully follow the instructions as described in the adapter set.
When the resistance of the flue pipe and air supply pipe increase, the appliance
power will decrease. The maximum permitted reduction in power is 5%.
The resistance of the air supply pipe and combustion gas flue depends on:
the length,
the diameter,
all components (bends, elbows,...).
The total permitted pipe length of the air supply and the combustion gas flue is
indicated for each appliance category.
Equivalent length for concentric installation (60/100)
Bend 90°
Bend 45°
Equivalent length for dual pipe installation
R/D=1
R/D=0.5
Length (m)
1.5
1
Bend 90°
Bend 45°
Elbow 90°
Elbow 45°
7
Unit installation
|
Length (m)
2 m
1 m
4 m
2 m
Installer reference guide
69

Advertisement

Table of Contents
loading

Table of Contents