7.10.4 To connect the electrical wiring to the indoor unit

CHYHBH05+08AF + EHYKOMB33A
Daikin Altherma R Hybrid
4P471761-1E – 2020.10
Wire type
Single-core wire
Stranded conductor wire
with round crimp-style
terminal
It is recommended to install all electrical wiring to the hydro box before installing
the boiler.
1 Wiring should enter the unit from the bottom.
2 Routing of the wiring inside the unit should be as follows:
Installation method
c b
A
a
a Curled single-core wire
b Screw
c Flat washer
c b
B
B
a
a Terminal
b Screw
c Flat washer
Allowed
NOT allowed
a
c
b
a
b
c
7
Installation
|
AA´
c
a
a
b
c