Information On; Installation Location; General Test Conditions; Electrical Connection - Bosch TTM 2104 Original Instructions Manual

Tire tread measurement device
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 32
5.

Information on

installation location

5.1

General test conditions

R
Only use the TTM 2104 / TTM 2204 indoors.
R
No dirt or moisture below the TTM 2104 / TTM 2204 .
R
The ground below the measuring unit must be
suitable for an installation with dowels and for
supporting the load of the central support.
R
The ground must be even (for tolerances see chap.
5.4).
i
Limitation due to sunlight:
$
Direct and intense solar radiation on the glass
plates impair exact measurement.
$
Remedy: Shading the measurement bay.
5.2

Electrical connection

Connection of the TTM 2104 / TTM 2204 in the electrical cabinet
must be done by a local specialist (230 V, 16 A).
Robert Bosch GmbH
Information on installation location | TTM 2104 / TTM 2204 | 37 | en
5.3
Fig. 2:
No.
1
2
3
4
5
5.4
Permissible height difference
Transverse direction (left to right)
Longitudinal direction (front to rear)
Diagonal direction
(front/rear to left/right)

Size

Dimensions of measurement bay and system
Designation
Screen/ Smart TV (special accessory)
Max. distance to TTM 2104 / TTM 2204
Electrical cabinet/ Switch and access
point
Max. distance to TTM 2104 / TTM 2204
Straight drive-down path, min. length
TTM 2104 / TTM 2204
Straight drive-up path, min. length

Ground evenness of measuring unit

1 691 206 005
Dimensions
8 m
8 m
3 m
1.03 x 2.245 m
3 m
Value [mm]
≤ 5
≤ 3
≤ 5
|
2019-02-25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ttm 2204

Table of Contents