7.2

Preventive maintenance

The maintenance work described below must be
performed by the user.
!
If components are damaged or worn or do not
function properly:
Inform the Bosch customer service or an
authorized service agent.
7.2.1

Service intervals

Component
Action
Labels
Visual inspection: All labels are
existent and clearly legible.
Measuring units
Visual inspection:
and ramps
Components are damaged.
Wiring
Visual inspection:
Insulation is damaged.
Measuring units
Cleaning the interiors of the
measuring units
Measuring units
Tighten screws on shear
connectors.
Measuring units
Adjust leg support.
Adsorber
Check the condition of the drying
agent.
Adsorber
Replace adsorber.
Slide protection
Check the condition of the slide
strip
protection strip.
Slide protection
Replace the slide protection strip. x
strip
7.2.2

Activate maintenance mode

1. Select <Settings>.
2. Select operation mode Maintenance in the General
information tab.
3. Select <Apply>.
"
The measuring unit lighting is turned off.
Robert Bosch GmbH
Maintenance | TTM 2104 / TTM 2204 | 43 | en
1 <Settings>
2 General information tab
3 Maintenance mode
4 <Apply>
7.2.3

Maintaining measuring units

x
1. Unhook drive-down ramps from measuring units:
x
to do so, lift both fillister head screws of the drive-
down ramps out of the measuring units' keyholes.
x
2. Open up the cover plates of the measuring units.
Cover plate stays open by itself after it has been
x
turned by approx. 110°.
3. Cleaning the internal spaces of the measuring units:
x
$
Remove course material such as leaves and other
x
small objects by hand.
$
x
Remove small objects with a vacuum cleaner.
4. After cleaning the interior: Check clearance below
x
the diagnosis modules with a feeler gauge. The
x
clearance must be approx. 2 mm.
Fig. 4:
Measuring unit with open cover plate
1 Diagnostic module
2 Frame
3 Cover plate
4 Drive-down ramp (unhooked)
5. Tighten screws of both measuring units on shear
connectors.
|
1 691 206 005
2019-02-25