Nvidia MSTFLINT Manual page 36

Burning and diagnostics tools
Hide thumbs Also See for MSTFLINT:
Table of Contents

Advertisement

Feature
RATE_REDUCE_MONITOR_PERIOD_P
1
RATE_REDUCE_MONITOR_PERIOD_P
2
The minimum time between 2
consecutive rate reductions for a
single flow. Rate reduction will occur
only if a CNP is received during the
relevant time interval
RPG_AI_RATE_P1
RPG_AI_RATE_P2
The rate, in Mbits per second, used to
increase rpTargetRate in the
RPR_ACTIVE_INCREASE state
RPG_BYTE_RESET_P1
RPG_BYTE_RESET_P2
Transmitted data between rate
increases if no CNPs are received.
Given in Bytes
CNP_RES_PRIO_MODE_P1
CNP_RES_PRIO_MODE_P2
If set, CNP packets for this port
contain priority from received request,
if unset, use value from cnp_802p_prio
RPG_GD_P1,
RPG_GD_P2
If a CNP is received, the flow rate is
reduced at the beginning of the next
rate_reduce_monitor_period interval
to,
(1-Alpha/Gd)*CurrentRate. RPG_GD is
given as log2(Gd), where Gd may only
be powers of 2
RPG_HAI_RATE_P1,
RPG_HAI_RATE_P2
The rate, in Mbits per second, used to
increase rpTargetRate in the
RPR_HYPER_INCREASE state
Parameter
Values
0 to 131071
2: Default
0 to 131071
10: Default
0 to 32767
0: Disabled
150: Default
True False
0 to 15
7: Default
0 to 131071
150: Default