Internal Ref.
No.
Discovered in Version: 4.12.0
1747607
Description: When using the mstfwreset tool to reset the firmware on the
BlueField card, the firmware is not synchronized between the host (SmartNIC
device) and the Arm side.
Workaround: N/A
Keywords: mstfwreset, BlueField
Discovered in Version: 4.11.0
1566872
Description: 64 bits parameters are currently not supported in mstconfig. Although
these parameters can be found in the nv_invalidate_all_timestamp TLV, that TLV
cannot be used to set the time parameter.
Workaround: N/A
Keywords: mstconfig
Discovered in Version: 4.11.0
1431471
Description: In ConnectX-5 adapter cards, the time-stamp capability using mstflint,
is supported only on the device using the "-d" flag, and not on the binary using the
"-i" flag.
Workaround: Use the "-d" flag to set the time-stamp.
Keywords: mstflint
Discovered in Version: 4.11.0
1442454
Description: Occasionally, when running mstfwreset over a Multi-Host device, the
driver remains down if the mstfwreset operation fails.
Workaround: N/A
Keywords: mstfwreset
Discovered in Version: 4.11.0
Issue