Internal
Ref. No.
795226/
Description: Occasionally, mst tools (driver mode) do not function after running
mstfwreset in PowerPC machines.
795657/
862607
Keywords: mstfwreset
Discovered in Release: 4.4.0
Fixed in Release: 4.6.0
795756/
Description: mstfwreset disables and enables all Mellanox devices' Network
Interfaces when resetting the firmware on a device that at least one of its network
795916
interfaces is up.
Keywords: mstfwreset
Discovered in Release: 4.4.0
Fixed in Release: 4.5.0
795479/
Description: Running mstfwreset against OEM devices may enter the device to a
undefined state.
795521
Keywords: mstfwreset
Discovered in Release: 4.4.0
Fixed in Release: 4.5.0
Issue