1-16
Dell PowerVault Storage Systems — Rack Installation Guide
c.
Secure the tray to the two back vertical rails by installing a 10-32 x 0.5-inch
screw with a #10 washer through the hole at the top of each flange.
SPS tray

Figure 1-13. Installing the 800-W SPS Tray in the Rack

4.
Secure the front of the tray to each front vertical rail (see Figure 1-13):
a.
Install the front tray mounting bracket by inserting the three tabs on the
bracket into three matching holes in the front vertical rails that you marked
in, "Marking the Location for the 800-W SPS Tray," found earlier in this
document.
b.
Ensure that the rear of the bezel mounting stud on the mounting bracket
projects through the matching hole in the tray flange.
c.
Secure the front mounting brackets to the front of the tray with four 10-32 x
0.625-inch Phillips-head pan-head screws.

Installing a Single 800-W SPS Unit in the Tray

NOTICE: In a rack mount system, the SPS unit(s) must be placed directly
beneath the enclosure to which it will be connected. It is assumed that the
SPS tray is mounted directly beneath the DPE.
10-32 x 0.5-inch Phillips-head screws
with #10 washers (2)
10-32 x 0.625-inch pan-head Phillips-head
screws (4)