Operation

Operation
NOTE: The table frequency is set at the manufacturer
for optimal part movement. The serial label above the
Control Display lists the SET FREQUENCY (Fset) of the
table when leaving the manufacturer. This Fset was
tested to give optimal movement on the left half and
right half of the table. If inconsistent part movement is
observed between the left half and right half of the table,
refer to Part Table Frequency, page 9.

Part Table Feed Rate

1. Place 4 to 20 parts on the table.
2. Turn the table ON either through the PLC M12 input
or manually, see Manual Operation in Override
Mode, page 14.
3. For course adjustment, PRESS AND HOLD the UP
or DOWN arrow key until the parts are moving close
to the desired feed rate. This directly changes the
Amplitude value.
8
4. For fine tune adjustment REPEATEDLY PRESS the
UP or DOWN arrow keys to dial in on the desired
feed rate. This directly changes the CFR Value.
5. Once the feed rate is determined, record the CFR
value of the part for future reference on the CFR
Value table provided on page 36.
6. When the feed rate is set, turn table OFF.
7. If the part does not move properly on the table, see
Difficult to Move Parts, page 9.

Hopper Feed Rate

1. Always turn the table ON when adjusting the hopper
feed rate.
2. Insert parts into the hopper.
ti21444a
3. Set hopper gate to desired location to control how
parts transfer from hopper to feed tray.