Default Memory

It may be necessary to get back to a known setting.
Once a feed system has been set up properly, the set-
ting should be manually saved into the "Save Settings1"
memory. If an operator disturbs the settings, the
"Restore Settings1" feature can restore the control to an
established set up. When different parts are used on the
same feed system, two other memory locations called
"Save Settings2" and "Save Setting3" can be used for
the second part. Operators can recall settings 1, 2, or 3
based on the part being used. Three memory locations
are available for software versions 1.15 and higher. The
"Factory Reset" selection will put the original factory set-
tings into the memory.

Language

The run display and programming menus can be set to
display in English, Spanish (Espanol), French (Fran-
cais), or German (Deutsch).
332462E

Over Current Protection

The control has a coarse over-current fault protection
that trips when the output is above the rated current.
The G-Flex 1500 is rated 1.8A at 120V. The operator
should monitor the output current to ensure that it is
within the desired range. If an "Over Current" occurs,
press the "1/0" key to restart the control. The operator
should also monitor the temperature of the coils on the
vibratory feeder. The coils should never be too hot to
hold.

CFR Set Point

The CFR set point sets the amplitude vibration level that
the control regulates to. The G-Flex 1500 control adjusts
the amplitude automatically to match the CFR set point.
The CFR set point can be adjusted by pressing the UP
and DOWN arrow keys. Hold an arrow key down to
adjust the amplitude setting instead of the CFR set
point.
The CFR set point only appears on the display when the
"Amplitude Source" menu under Power Settings is set to
"Auto Track" and the CFR sensor is attached. The fea-
ture is included on Version 1.05 software and greater.
Detailed Control Adjustment