Detailed Control
Adjustment
NOTE: The following section covers advanced pro-
gramming operating instructions that should only
be used in highly unique applications.

Amplitude Power Setting

Output power is controlled by the up and down arrow
keys. Power setting can be adjusted with the keys
unless the security feature lock has been selected.
Once the proper security code has been entered, the
power setting may be adjusted under Power menu.
NOTE: The power setting may not be above the maxi-
mum power setting or below the lower power setting
level. The amplitude power setting is displayed in the
following manner: "A=50.0%"

Limiting Maximum Output of Control

The Max Amplitude setting can be adjusted to keep a
vibratory feeder from hammering or vibrating exces-
sively when the control is turned up to full power. The
maximum power setting can be found under the Power
menu. It can be adjusted from 100.0% down to 40.0%.
Amplitude will continue to increase if the system cannot
get back to desired vibration level. Use the CFR feature
to limit the Max Output level to prevent the feeder coil
from overheating and damaging the feeder.
332462E
NOTICE

Setting Minimum Output of Control

The Min Amplitude setting can be adjusted to the
desired low level of vibration. The minimum power set-
ting can be found under the Power menu. It can be
adjusted up from 0.0% to 95.0%. NOTE: The software
does not allow the minimum level to be within 5.0 counts
of the maximum level.

Soft-Start

The start-up of the control output can be adjusted to
gradually build up to the desired output level, rather than
starting abruptly. The soft start setting can be found
under Power Settings menu. The soft-start can be set
from 0.0 to 10.0 seconds. Factory default is 0. Changing
the soft-start can adversely affect the cycle time of the
part finding sequence.

CFR Positive and Negative Gain

The CFR Positive and Negative Gain settings control
the rate that the feeder vibration level is corrected by the
control. When the vibration decreases below the set
point, the "CFR Positive Gain" sets the rate at which the
output gets boosted to compensate for a vibration
decrease. When the vibration increases, the "CFR
Negative Gain" sets the rate at which the output gets
lowered to compensate for a vibration increase. If either
the CFR Positive or Negative gain is set too low, it will
take longer than desired to get back to the original feed
rate. If either gain is set too high, the control may
over-shoot beyond the original feed rate. The CFR
Positive and Negative Gain settings effect control
operation when the CFR sensor is used, and the
"Amplitude Control" is set to "Auto Track".

Detailed Control Adjustment

15