Electromagnet and Armature
Spacing
The spacing between the electromagnet and armature
must be .090 in.
ti21773a
1. To adjust, loosen the two bolts on the electromagnet
mount and adjust to appropriate spacing.
2. Retighten the two bolts and torque to 150±10 in-lb.

Spring Replacement

Table
332462E
.090 in.
ti21996a
44
103
ti22021a
12 places
24
26
25
1. Remove screws (44, 103, 104) holding spring pack
(30, 24, 26, 25, 102).
2. Remove and replace spring pack, replace screws
(44, 103) - hand tighten only. Be sure to install three
thicker springs (25) and two thinner springs (26)
with spacers (24) in the order shown.
3. Level table front to back and left to right with other
table half. Ensure proper spacing between the two
halves of the part table.
4. Torque spring mounting screws (44, 103) to
140-160 in-lb.
5. Install and torque screws (104) to 190-210 in-lb.
Hopper
8
6
9
10
1. Remove screws (10) holding spring pack (9, 6, 8).
2. Remove and replace spring pack, replace screws -
torque to 190-210 in-lb. Be sure to install parts in the
order shown.