General Information; Control Menu; Power Setting; Display Abbreviations - Graco G-Flex 1500 Operation - Repair - Parts

Feeder
Hide thumbs Also See for G-Flex 1500:
Table of Contents

Advertisement

General Information

Control Menu

The control uses four programming keys to operate the
control. The power key controls manual operation in
override mode.
Key
ENTER - Allows entry to menu and access to
adjust each setting. Push and hold the enter
key to enter program mode. If security feature
has been enabled, enter proper code. Once
inside the menu, the enter key selects a menu
item or a parameter to adjust. Any changes to
the settings are saved at power-down.
BACK - Moves the current menu location up
one level higher than it was before. It is also
used to get back to the normal operating dis-
play.
Arrow Down - Allows the user to step down
through the program menu or decrease a set-
ting.
Arrow Up - Allows the user to step up through
the program menu or increase a
setting.
Power - Allows the user to temporarily stop or
to start control operation. When the LCD status
reads "Stop/Run", hold the power key down for
just over a second and the control will start the
override operation. In override mode, the hop-
per or table turns on regardless of input con-
nection and signal from the PLC at the M12.
NOTE: See Control Menu Layout, page 13, for the menu
structure. When in menu mode and no keys are pressed for
one minute, the display reverts to normal
operating display mode.
332462E
Function

Power Setting

The G-Flex 1500 comes from the factory set to "Auto
Track" for Amplitude Source. This allows the user to
adjust the CFR (Constant Feed Rate) value to the
desired feed rate. The control will automatically adjust
the Amplitude to ensure a constant feed rate even as
the parts load changes. The amplitude and frequency
can be changed to Manual adjustment if desired (see
Control Menu Layout, page 13).

Display Abbreviations

CFR = Constant Feed Rate
A = Amplitude
F = Frequency
General Information
ti22342a
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

16v133

Table of Contents