Operation
Operation
Model 243701 Header
The inlet valve is "air to open" and "air to close" valve.
This valve must be operated by a 4–way solenoid valve.
Four–way solenoids with a 24" (60 cm) and high tem-
perature air tubes are listed in Accessories on page 13.
No drip valves (26) are provided to stop the adhesive
from dripping when the laminator is shut down for clean-
ing. These valves must be manually shut off. Be sure to
open the valves (26) before trying to dispense more
adhesive.
309181H