Control Menu Layout

Normal Operation Display
Press and hold 'Enter' to enter the program menu or get the security menu.
Use the arrow up and down keys to adjust the security number. Press enter to test the security number.
Main Menu
Power Settings
Frequency Settings
Timer Settings
Power Key Interface
Diagnostics
Security
Defaults
Language
Status Line Message
Constant Feed Rate (CFR)
Amplitude
Frequency
The normal operating display shows the status of the control with regard to input signals and control settings. They are listed from highest to
lowest in priority. The highest priority message takes precedence over all other messages.
Stop/Run - The Power button has been pushed to disable control operation.
Override - The Power button has been pushed and held so the control will feed without interruption from the "Sensor" or "Run" inputs.
Run Input - The run jumper has not been made.
Zero Speed - The output is off because the output is set to 0.0%.
Run - The feeder is running normally.
Run/CFR - Constant Feed Rate sensor is regulating the feed rate (Autotune
332462E
Sub Menu
Adjustments
Amplitude
[ 0.0 to 100.0 ]%
Max Amplitude
[ 100.0 to 40.0 ]%
Min Amplitude
[ 0.0 to 95.0 ]%
Soft Start Time
[ 0.0 to 10.0 ] Seconds (0.0 Default)
Amplitude Source
[ Auto Tracking Manual, 0-10V, 4-20mA ]
CFR Positive Gain
[ 25 Default ]
CFR Negative Gain
[ 5 Default ]
Frequency
[ 5.0 to 140.0 ] Hz (60.0 Hertz Default)
Max Frequency
[ 15.0 to 140.0 ] Hz (140.0 Hertz Default)
Min Frequency
[ 5.0 to 130.0 ] Hz (45.0 Hertz Default)
Frequency Mode
[ Auto Tracking, Manual ]
Auto Scan
[ Press ENTER to perform an automatic frequency scan ]
Resonate Threshold Level [ 200 Default ]
Auto Track Dead Band
[ 64 Default ]
On Delay
[ 0.0 to 20.0 ] Seconds (0.0 Default)
Off Delay
[ 0.0 to 20.0 ] Seconds (0.0 Default)
Empty Bowl Timer
[ 5 to 255 ] Seconds (10 Default) **Not used on G-Flex 1500
Sensor Polarity
[ Inverted, Normal ]
Sensor Type
[ Auto, NPN, PNP ]
Run Mode
[ Normal, Always On, 2-Speed, High/Low ]
Empty Bowl
[ Normal, Stop ] **Not used on G-Flex 1500
Aux Output Mode
[ Normal, Inverted, Alarm, Inv Alarm, Air Jet ] **Not used on G-Flex 1500
Software Version
[ Software Revision Level ]
Accelerometer
[ data ]
Over Amps
[ data, data ]
DC Volts
[ data ]
Internal Temperature
[ data ] °C
Keypad Lock
[ Unlocked, Amplitude Only, Locked ]
Security Code
[ 000 to 999 ]
Restore Settings 1
[ 'Enter' Restores User Settings 1 ]
Restore Settings 2
[ 'Enter' Restores User Settings 2 ]
Restore Settings 3
[ 'Enter' Restores User Settings 3 ]
Save Settings 1
[ 'Enter' Saves User Settings 1 ]
Save Settings 2
[ 'Enter' Saves User Settings 2]
Save Settings 3
[ 'Enter' Saves User Settings 3]
Factory Reset
[ 'Enter' Resets Control to Factory Default Settings (Shown in bold) ]
Pick Language
[ English, Spanish, French, German ]
Normal Display Message Priority
Gun/CFR
R = 1
S = 1
CFR=024.5
A= 40.0%
O = 1
A = 1
F= 60.0 Hz
Run Input: 1=on/closed & 0=off/open
Sensor input: 1=on/closed & 0=off/open
Output to vibratory feeder: 1=on & 0=off (Not used on G-Flex 1500)
Aux Output: 1=on & 0=off (Not used on G-Flex 1500)
®
).
Operation
**Auto Tracking or Manual only on G-Flex 1500