Installation

Wiring Connections

Improper grounding setup or usage of the system can
cause electric shock. All electrical wiring must be done
by a qualified electrician and comply with all local
codes and regulations.
Supply Wiring Connections
Connect power to the G-Flex 1500 at the Power-in Junc-
tion Box (R). See Component Identification, page 4,
for location of Junction Box. Use a minimum of 14 AWG
solid wires from the power supply. Insulation strip length
is 0.43 in. (11 mm). Connect the Hot (L1), Neutral (N),
and Ground
wires to coincide with the G-Flex 1500
wires at the terminal block.
Ensure all connections are secure and install the cover
on the junction box.

PLC Interface

The G-Flex 1500 is designed to be PLC controlled
through the M12 5-Pin connector. Refer to the M12 Pin
Diagram for details about the M12 connector.
6
M12 Pin Diagram
Connector on Housing
(4)
(1)
The table and hopper signal must be between 5-30
VDC. The common signal is 0 VDC.
To run the unit without PLC control, see Manual
Operation in Override Mode, page 14.
To run the unit with PLC control, press the Power Key
once.
The control display will then show Run Input to indicate
PLC control.
ti21441a
ti21994a
(5)
1 Not Used
(3)
2 Table Signal
(5-30 VDC)
3 Common
(0 VDC)
4 Hopper Signal
(2)
(5-30 VDC)
5 GND
Pin-out
ti22338a
332462E