Clavia Nord Modular V3 User Manual page 188

Clavia nord modular v3: user guide
Table of Contents

Advertisement

7. Module reference: Sequencer group
S S S S
E E E E Q Q Q Q U U U U E E E E N N N N C C C C E E E E R R R R G G G G R R R R O O O O U U U U P P P P
The sequencer modules can perform different functions during the course of a specified time. The se-
quencer modules in the Nord Modular system has 16 steps. They can be linked together in series to pro-
vide longer sequences and they can be clocked by various clock sources, originating from other modules
or from the MIDI clock. The sequencer modules can be synchronized to each other in a number of ways.
The performance of the sequencer modules is not transmitted at the MIDI output. Read more about
some of the possible combinations with the sequencer modules at the end of this chapter.
E E E E
S S S S
V V V V E E E E N N N N T T T T
E E E E Q Q Q Q
This is a trigger sequencer. Each step can send two separate logic pulses on the two separate outputs. Ac-
tivate a step by clicking on one or more of the 32 available trigger buttons.
C C C C
L L L L K K K K
This is the yellow input for the clock pulses. These pulses will advance the sequencer one step for each
pulse.
R R R R
S S S S T T T T
This is a yellow input where a high logic signal will reset the sequencer (force it to step 1 again). The
restart isn't performed until the next the clock pulse is received at the Clk input. This guarantees perfect
timing.
S S S S
N N N N C C C C
This yellow output transmits a high logic signal whenever a sequence starts from step 1.
Signal: Logic.
C C C C
L L L L R R R R
Pressing this button will reset every trigger button in the two rows.
L L L L
O O O O O O O O P P P P B B B B U U U U T T T T T T T T O O O O N N N N
If the loop mode is on, the Event sequencer will automatically restart from step 1 after the last step. If the
loop mode is off, the sequencer will stop at the last step.
S S S S
T T T T E E E E P P P P
Set the last step in the sequence. The sequencer will return to step 1 if loop mode is on, or stop if loop
mode is off. Set the last step with the buttons. Range: 1 to 128 steps.
L L L L
I I I I N N N N K K K K
This yellow output transmits a high logic signal whenever the Event sequencer goes beyond step number
16. This is used for linking several Event sequencers in series. See more about linking at the end of this
chapter.
Signal: Logic.
Page 180
NORD MODULAR V3.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nord modular v3.0

Table of Contents