Clavia Nord Modular V3 User Manual page 141

Clavia nord modular v3: user guide
Table of Contents

Advertisement

NORD MODULAR V3.0
S S S S
Sets the sustain level. This level will be held (sustained) for as long as the logic Gate signal is high. When
the logic Gate signal drops to zero, the envelope will proceed with the release stage. The sustain level is
displayed in 'units' in the corresponding display box. Range: 0 to 64 units.
R R R R
Sets the release time. When the logic Gate signal drops to zero, the envelope will decrease from the sustain
level to zero with the release time. The release is exponential. The release time is displayed in milliseconds
or seconds in the corresponding display box. Range: 0.5 ms to 45 s.
A, D, S, R
A, D, S, R
A, D, S, R
A, D, S, R
C C C C O O O O N N N N T T T T R R R R O O O O L L L L I I I I N N N N P P P P U U U U T T T T S S S S
Each of the attack, decay, sustain and release values can be controlled externally by using the correspond-
ing control signal input below the A, D, S and R knobs. You can adjust the level of each control signal
by turning the corresponding rotary knob. Note that the A, D and R control inputs handles bipolar con-
trol signals. Positive control signals shortens the times and negative control signals increase the times.
G G G G R R R R A A A A P P P P H H H H
The info graph shows an approximation of the envelope gain curve. The yellow line represents the sustain
level, which is not defined in time since it depends on the gate signal hold time.
I I I I
N N N N V V V V E E E E R R R R T T T T
This inverts the control signal of the envelope.
I I I I N N N N P P P P U U U U T T T T
The red audio signal input. Here you patch a signal to the envelope controlled amplifter.
E E E E
N N N N V V V V E E E E L L L L O O O O P P P P E E E E O O O O U U U U T T T T P P P P U U U U T T T T
The blue control signal output from the envelope generator.
Signal: Unipolar.
O O O O
U U U U T T T T P P P P U U U U T T T T
The red output from the envelope controlled amplifter.
Signal: Bipolar.
AHD-E
AHD-E
AHD-E
AHD-E
N N N N V V V V
The Attack-Hold-Decay envelope is an envelope with inputs to control attack, hold and release times.
T T T T
R R R R I I I I G G G G I I I I N N N N P P P P U U U U T T T T
A logic control signal input that is used to start the envelope. Note that this is a Trig input and not a gate
input. This means the envelope will always complete all the envelope stages. A green LED indicates when
a trig signal is received
[A
[A
[A
[A
T T T T
I] I] I] I]
T T T T T T T T E E E E N N N N U U U U A A A A T T T T O O O O R R R R
Y Y Y Y P P P P E E E E
7. Module reference: Envelope group
Page 133