The Logic Inverter module produces a logic low or high signal depending on the input value. When an
incoming signal is between +1 and +64 units, the module transmits a low logic signal. When an incoming
signal is between 0 and -64 units it transmits a logic high signal.
I I I I
N N N N P P P P U U U U T T T T
When an incoming signal is between +1 and +64 units, the module transmits a low logic signal on the
output. When an incoming signal is between 0 and -64 units it transmits a logic high signal.
O O O O
U U U U T T T T P P P P U U U U T T T T
Signal: Logic.
L L L L
P P P P
O O O O G G G G I I I I C C C C
R R R R O O O O C C C C
This Logic Processor module transmits a high logic signal whenever any incoming signals meet a condi-
tion set by you. The input signals are considered "high" at any value equal to, or above, +1 unit. The
transmitted logic signal will be high for as long as the incoming signals meet the condition.
C C C C
O O O O N N N N D D D D I I I I T T T T I I I I O O O O N N N N B B B B U U U U T T T T T T T T O O O O N N N N S S S S
AND produces a high logic signal when the two incoming signals, each with a level greater than 0 units,
is present at the two inputs at the same time.
OR produces a high logic signal if at least one signal, with a level greater than 0 units, appears at the in-
put(s).
XOR produces a high logic signal when only one signal, with a level greater than 0 units, appears at one
of the inputs.
I I I I
N N N N P P P P U U U U T T T T S S S S
The two yellow inputs of the Logic processor module.
O O O O
U U U U T T T T P P P P U U U U T T T T
Signal: Logic.