29. Check the movement at the paper edge from the leading to trailing edges, and turn the adjusting screws of
the correction plate to adjust the internal multi-fold unit's position until the deviation stays within 2
markings on the scale. (Each marking represents 1 mm.)
•
[A]: When the paper edge shifts towards the front, turn the adjusting screw clockwise.
•
[B]: When the paper edge shifts towards the rear, turn the adjusting screw counterclockwise.
30. After registration, tighten the coin screw [A] to secure the internal multi-fold unit.
When you fully open the front cover of the internal multi-fold unit, it may interfere with the machine's
upper front cover, causing the internal multi-fold unit to become misaligned. Therefore, tighten the screw
[A] with a stubby screwdriver.
Internal Multi-fold Unit FD3000 (M482-17)
125