Series commissioning and operation
8.1 Transfer of the frequency converter parameter assignment
8.1.4

Parameter transfer with PC (STARTER)

Upload from frequency converter to the PC
Parameters are uploaded from the frequency converter's RAM to a project file on a PC's
hard disk using STARTER. STARTER can be connected via a fieldbus or directly to the
frequency converter's RS232 interface.
Prerequisites
● You must have a converter with a suitable parameter set at your disposal (upload
converter).
● STARTER must be installed on the PC used for standard commissioning.
● The upload converter's power supply must be connected.
● The upload converter is in the "Ready to run" state.
Connect the STARTER PC to the upload frequency converter via RS232 (point-to-point
connection, appropriate connecting cable required) or via fieldbus, press the online button
Remark
An online connection can only be established between the PC and frequency converter via
fieldbus if the following conditions are met:
● The interface module of the ET 200 station is running in DPV1 mode.
● There is no CPU between the PC and the frequency converter (also applies to the
Download from PC to the frequency converter
In the case of a manual download, all parameters (with the exception of fail-safe parameters)
will be transferred to the frequency converter.
136
("Connect to target system") and perform the upload using the
button.
Operating Instructions, 07/2016, A5E01100763B AC