Siemens SIMATIC S7-1500 Manual
Hide thumbs Also See for SIMATIC S7-1500:

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC S7-1500

  • Page 2 Preface Documentation guide SIMATIC Description Mounting S7-1500, ET 200MP Active backplane bus ST 1+12 slot, active backplane bus ST 1+8 slot, Operation active backplane bus ST 1+4 slot Configure Equipment Manual Maintenance and service Alarm and system messages Technical specifications Dimension drawings Spare parts/accessories List of I/O modules...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Preface

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are Active backplane bus ST 1+12 slot, active backplane bus ST 1+8 slot, active backplane bus ST 1+4 slot...
  • Page 5 Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed visit (https://www.siemens.com/industrialsecurity). Open Source Software Open-source software is used in the firmware of the I/O modules.
  • Page 6: Table Of Contents

    Table of contents Preface ..............................3 Documentation guide ..........................6 Description ............................. 8 Application area and function ....................8 Properties ..........................9 Mounting ............................. 11 Operation ............................. 15 Configure ............................. 17 Configure .......................... 17 Configuration of the active backplane bus in the TIA Portal ..........18 Maintenance and service........................
  • Page 7: Documentation Guide

    This arrangement enables you to access the specific content you require. Basic information The System Manual and Getting Started describe in detail the configuration, installation, wiring and commissioning of the SIMATIC S7-1500 and ET 200MP systems. The STEP 7 online help supports you in the configuration and programming. Device information Product manuals contain a compact description of the module-specific information, such as properties, wiring diagrams, characteristics and technical specifications.
  • Page 8 Documentation guide Manual Collection S7-1500/ET 200MP The Manual Collection contains the complete documentation on the SIMATIC S7-1500 automation system and the ET 200MP distributed I/O system gathered together in one file. You can find the Manual Collection on the Internet (https://support.industry.siemens.com/cs/ww/en/view/86140384).
  • Page 9: Description

    Description Application area and function Benefits The benefits of the active backplane bus are: • Reaction-free replacement of a defective module: – Without the CPU reporting a station failure – Without disturbing modules in the station • Startup with one or more module gaps. You have the option of plugging in additional modules later.
  • Page 10: Properties

    Description 2.2 Properties • Applications in which plant operation must be maintained as long as possible, for example, when a service technician is not immediately available. – Offshore installations (oil platforms) – Compressors along gas pipelines that maintain the working pressure •...
  • Page 11 Description 2.2 Properties Properties The active backplane bus can be used with: Designation Article number As of hardware functional as of firmware version status IM 155-5 PN HF 6ES7155-5AA00-0AC0 FS01 V4.4 Digital input modules DI and F-DI See List of I/O modules (Page 26) Digital output modules DQ and F- Analog input modules AI Analog output modules AQ...
  • Page 12: Mounting

    Mounting Required mounting rail The following table and diagram help you to select the matching mounting rails for the active backplane bus used. Active backplane bus Length of Minimum length of mounting rail Pre-assembled mounting station l rail (2 m rail for cutting to length) Active backplane bus ST 1+4 slot 175 mm 210 mm for pre-mounted modules...
  • Page 13 Mounting Mounting the mounting rail Note No screws behind the active backplane bus Note that behind the active backplane bus, no screws are available for mounting the mounting rail. Otherwise, the active backplane bus cannot be mounted. System power supply With active backplane bus, a system power supply supplies power to the entire station.
  • Page 14 Mounting 3. Hook the interface module on the rail. You may only plug in one interface module. The interface module must be plugged into the first slot. 4. Swivel the interface module downwards so that the contacts are connected to the active backplane bus.
  • Page 15 Mounting 11. If you have empty slots on the active backplane bus, then you must provide these slots with a slot protection (see Operation (Page 15)). 12. A "BACKPLANE" sticker is enclosed for the active backplane bus. Use this sticker to identify the interface module.
  • Page 16: Operation

    3. Then you may pull the I/O module. 4. When plugging in, proceed in reverse order (see also S7-1500 Automation System system manual (https://support.industry.siemens.com/cs/ww/en/view/59191792)). Pulling and plugging power supply module A power supply module cannot be pulled and plugged without reaction.
  • Page 17 Operation See product information Deployment of the modules in zone 2 hazardous atmospheres (https://support.industry.siemens.com/cs/ww/de/view/19692172). Slots of I/O modules They have an installation with empty slots. You can plug in additional I/O modules during operation. Active backplane bus ST 1+12 slot, active backplane bus ST 1+8 slot, active backplane bus ST 1+4 slot...
  • Page 18: Configure

    Configure Configure Configure You configure the IM 155-5 PN HF interface module with STEP 7 or the configuration software of another manufacturer. Configuration software STEP 7 (TIA Portal) GSD file • TIA Portal V16 with HSP0318 • GSDML V2.34 for the active backplane bus ST 1+12 for the active backplane bus ST 1+12 •...
  • Page 19: Configuration Of The Active Backplane Bus In The Tia Portal

    Configure 5.2 Configuration of the active backplane bus in the TIA Portal Configuration of the active backplane bus in the TIA Portal The representation of a station in the graphics area of the device view consists of 2 main areas: ①...
  • Page 20 Configure 5.2 Configuration of the active backplane bus in the TIA Portal ① Rack area ② Module area (slots) Note Contrary to plugging modules, the replacement of a rack cannot be started by double-clicking on the catalog entry. The reason for this is that a double-click only works if there is slot free and permitted available.
  • Page 21: Maintenance And Service

    Maintenance and service Cycle for pulling and plugging The active backplane bus serves to increase the system availability. It is designed for occasional pulling and plugging of I/O modules for expansion or in case of faults. Active backplane bus ST 1+12 slot, active backplane bus ST 1+8 slot, active backplane bus ST 1+4 slot Equipment Manual, 07/2020, A5E46240468-AB...
  • Page 22: Alarm And System Messages

    Alarm and system messages Pull/plug interrupt Each pulling and plugging action of a configured module results in a pull/plug interrupt. OB 83 is started when a configured module is pulled in RUN mode. If OB 83 is not programmed, the CPU switches to STOP. When plugging a module into a configured slot in the RUN state, OB 83 is started and the parameter assignment is made if the module matches.
  • Page 23: Technical Specifications

    The following table shows the technical specifications as of 07/2020. On the Internet, you will find a data sheet with technical specifications that are updated daily for the active backplane bus ST 1+12 (https://support.industry.siemens.com/cs/de/en/pv/6ES7590-0BL00- 0AA0/td?dl=en), active backplane bus ST 1+8 (https://support.industry.siemens.com/cs/de/en/pv/6ES7590-0BH00-0AA0/td?dl=en) and active backplane bus ST 1+4 (https://support.industry.siemens.com/cs/de/en/pv/6ES7590- 0BD00-0AA0/td?dl=en). Article number...
  • Page 24 A current list of S7-1500 I/O modules that can be operated at elevations above 2,000 m can be found in the product information SIMATIC S7-1500/ET200 MP product information "Using the S7-1500 automation system / ET 200MP distributed I/O system over 2000 m above sea level"...
  • Page 25: Dimension Drawings

    Dimension drawings Dimension drawing of active backplane bus This section contains a dimension drawing of the active backplane bus mounted on a mounting rail. ① Length of active backplane bus ST 1+12 ② Length of active backplane bus ST 1+8 ③...
  • Page 26: Spare Parts/Accessories

    Spare parts/accessories Spare part compatibility If spare parts are required, you can replace the active backplane bus ST 1+8 slot with: • Active backplane bus ST 1+12 slot If spare parts are required, you can replace the active backplane bus ST 1+4 slot with: •...
  • Page 27: List Of I/O Modules

    List of I/O modules List of interface modules The following table contains the IM 155-5 PN and the HW and FW versions starting at which it can be used. Designation Article number as of hardware functional as of firmware ver- status sion IM 155-5 PN HF...
  • Page 28 List of I/O modules Designation Article number as of hardware functional as of firmware ver- status sion AI 8xU/I/R/RTD BA 6ES7531-7QF00-0AB0 FS01 V1.0.0 AI 8xU/I/R/RTD/TC HF 6ES7531-7PF00-0AB0 FS01 V1.0.0 AI 4xU/I/RTD/TC ST 6ES7531-7QD00-0AB0 FS01 V1.0.0 AI 8xU/I HS 6ES7531-7NF10-0AB0 FS01 V1.0.1 AI 8xU/I HF 6ES7531-7NF00-0AB0...
  • Page 29: Index

    Index Pulling and plugging I/O modules, 15 Interface module, 1 Power supply module, 15 Accessories, 10, 25 Active backplane bus Installing, 12 Application, 8 Article number, 9 Replacing racks, 2 Benefits, 8 Slot protection, 1 Slots, 12, 16 Configure, 1 Cycle for pulling and plugging, 20 Technical specifications, 22 Dimensional drawing, 24...

This manual is also suitable for:

Simatic et 200mp

Table of Contents