Connecting The Power Cord On An M35 Processor, 220 Volts Only - Kodak X-OMAT M35 Installation Instructions Manual

Processors
Hide thumbs Also See for X-OMAT M35:
Table of Contents

Advertisement

• Dangerous voltage.
• Possible damage from electrostatic
discharge.
[1]
Check and use the Local Electrical Codes.
[2]
Disconnect the main power at the wall.
[3]
Move the MAIN POWER SWITCH to the
''OFF'' position.
[4]
Remove the TOP COVER and the drive SIDE
PANEL, not shown.
[5]
Open the ELECTRICAL BOX DOOR.
[6]
Move wire No. 8A to the correct terminal on
TB5.
[7]
Move JUMPER 8:
Volts
200 or 208
220
240
FRONT PANEL
981159
Connecting the Power Cord on an M35 Processor,
220 Volts Only
Position of
Jumper 8
TB5-2
TB5-3
TB5-4
ELECTRICAL BOX
[8]
Apply the correct DATA STRIP inside the
ELECTRICAL BOX DOOR to indicate the
correct supply voltage.
[9]
Install the STRAIN RELIEF BRACKET inside
the processor. See the illustration below.
[10]
Feed the CABLE through the FRONT PANEL.
[11]
Insert the CABLE through the STRAIN
RELIEF.
[12]
Install the STRAIN RELIEF to the STRAIN
RELIEF BRACKET with the NUT.
[13]
Feed the CABLE into the ELECTRICAL BOX.
[14]
Connect the incoming wires to L1, L2, and N
of TB1. See the connection charts on the
circuit diagrams on pages 29 and 30.
[15]
Connect the ground wire to the GROUND
LUG. See the illustration on the next page.
[16]
Install the 2 WIRE TIES to the CABLE and
the STRAIN RELIEF.
[17]
Close the ELECTRICAL BOX DOOR.
[18]
Install the drive SIDE PANEL and the TOP
COVER.
CABLE
NUT
STRAIN RELIEF
STRAIN
RELIEF
BRACKET
H112_0162BCA
H112_0162BA
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

X-omat m35a