Filling the Tanks
[1]
Soak the DEVELOPER FILTER for
30 seconds in warm water.
[2]
Insert the DEVELOPER FILTER into the
FILTER HOUSING.
[3]
Check that the O-RING is seated correctly, or
leakage may occur.
[4]
Tighten the CAP and install the FILTER
HOUSING in the processor.
[5]
Check that the tubing is not kinked.
• Mix the developer first, then the fixer.
• Wash the mixing equipment thoroughly
between solutions to avoid contamination of
the solutions.
• Rinse the mixing and filling equipment
before each use.
• Fill the FIXER TANK first.
[6]
Install the SPLASH GUARD between the
DEVELOPER TANK and the FIXER TANK.
Splash Guard Installed Between the Developer
and Fixer Tanks
28
SPLASH
GUARD
H112_0117ACA
H112_0117AC
CAP
O-RING
DEVELOPER
FILTER
FILTER
HOUSING
H112_0093CCB
H112_0093CA
981159