Omron NJ Series Network Connection Manual page 43

Ethernet/ip connection guide
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

4
Enter 00404000 in the Modify
Column of
EIPOutput.CommandCode.
(Command code[0040](+ 7 words)
[4000] (+ 6 words): (System data
acquisition)
Enter 900 in the Modify Column of
EIPOutput.CommandParam1.
(Data number[900]: The number of
decimal places)
By pressing the Enter Key, the value
is set and the online value of
EIPOutput.CommandCode changes
to 00404000.
Click TRUE in the Modify Column of
EIPOutput.CommonControlFlag.F[0
](EXE).
The online value changes to True.
(EIPOutput.CommonControlFlag.F[
0](EXE): Control command
execution bit)
5
The values of
EIPInput.CommonStatusFlag.F[0](F
LG), EIPInput.CommandCodeEcho
and EIPInput.ResponseCode are as
follows:
•EIPInput.CommonStatusFlag.F[0
](FLG): [TRUE]
•EIPInput.CommandCodeEcho:
[00404000]
(The sent command code is
returned.)
•EIPInput.ResponseCode: 0
(The execution result of the
command (0: OK,
-1(FFFFFFFF): NG) is
reflected.)
•EIPInput.ResponseData:1
(The number of decimal places)
7. Connection Procedure
40