7.6.2. Checking Data That Are Sent and Received
Confirm that the correct data are sent and received.
Always confirm safety at the destination node before you transfer a user
program, configuration data, setup data, device variables, or values in memory
used for CJ-series Units from the Sysmac Studio.
The devices or machines may perform unexpected operation regardless of the
operating mode of the CPU Unit.
1
Select Watch Tab Page from the
View Menu.
2
The Watch Tab Page 1 is displayed
in the lower section of the Edit
Pane.
3
The following names are entered in
the Watch Tab Page 1 for
monitoring.
EIPOutput.CommonControlFlag
.F[0](EXE)
EIPOutput.CommandCode
EIPOutput.CommandParam1
EIPInput.CommonStatusFlag
.F[0](FLG)
EIPInput.CommandCodeEcho
EIPInput.ResponseCode
EIPInput.ResponseData
7. Connection Procedure