Replacing basic chassis components

Replacing the power supply

Introduction
The power supply is hot-swappable. This means that you can replace the
power supply without powering down the server.
Requirements
Before hot-swapping a power supply, gather the following tools:
one flat-blade screwdriver
one Phillips screwdriver
one antistatic wrist strap
the replacement power supply
When to hot-swap the power supply
A green LED indicates that the power supply is working properly. If the
green LED on the power supply module is unlit or red, the module is failing
or has failed. Other indicators of failure are the alarm that sounds and the
power supply module LED on status display that turns red.