11 May, 2001
[A]
B047I001.WMF
B047I104.WMF
3. Remove all the tape strips [A] as shown.
4. Open the original feed unit [B].
5. Remove the cushion [C] and close the original feed unit.
6. Release the lock levers [D] and open the paper path section [E].
7. Remove the right upper cover [F] (2 screws).
8. Remove the drum protection sheet [G] and remove the screw [H]. This applies
cleaning blade pressure to the drum.
NOTE: Be sure to remove the protective sheet before removing the pressure
screw. Otherwise, the cleaning blade will clamp the sheet to the drum,
and the drum may be damaged.
9. Open the fusing exit section [I]. Remove the two strips of shipping tape [J] and
the protection sheet [K].
10. Remove two strips of shipping tape [L]. Close the paper path section and fusing
exit section.
INSTALLATION PROCEDURE
[B]
[C]
[D]
[J]
[A]
[L]
[K]
[G]
[H]
3-7
[I]
[D]
[J]
B047I103.WMF
[F]
B047I105.WMF
[E]
[L]

Advertisement