9.6.4. Step Settings
This section describes the step settings for communications sequence No. 900. The se
include Retry Count, Send/Receive Messages (message names), Next Proces
P
rocess. The sequence of this protocol macro data includes Step No.00 only.
Additional Information
For details on the sequence settings, refer to 3-3 Step
(Cat. No. W344).
Manual
●R
etry Count setting
This se
ction describes the Retry count of the step. The step is retried for the specified
n
umber of times (0 to 9 times) when an error occurs. If the error occurs after retries, the step
moves to Error Process.
The retry count is enabled for the Send&Receive command only.
<Step setting screen>
<Settings
>
Step No.
0
0
●Send/receiv
e message (
This secti
o
n describes the
pre-registered send message name and matrix name are selected.
<Step setting screen>
<Settings>
Step No.
00
*<> in the receive message column indicates the matrix name. When there are two or
more receive message formats, use the matrix.
Retry count
3
massag
e name) settings
se
ttings for the Send/Receive Messages of the step. Here, a
Send message
SD_GETRVER
Attributes in the CX-Protocol Operation
Receive message
<GetVer_Mat>