Omron Sysmac CJ Series Connection Manual page 70

General-purpose serial connection guide (rs-232c)
Hide thumbs Also See for Sysmac CJ Series:
Table of Contents

Advertisement

9.6.3. Sequence Settings
This protocol macro data reads the product type and version by using co
s
equence No. 900. Set the timeout periods for the communications sequence.
Additional Information
For etails on sequence settings, refer
d
the CX-Protocol Operation Manual (Cat. No. W344)
●Time
out period setting
The settings of the timeout periods (Timer Tr
be
low.
[Communications sequence setting screen]
<Settings>
Item
Description
Receive wait
Timer Tr
monitoring time
Receive finish
Timer Tfr
monitoring time
Send finish
Timer Tfs
monitoring time
Additional Information
Refer to Section 4-5 Calculation Method of Monitoring Time of the CX-Protocol Operation
Manual (Cat.No. W344) for the calculation method of monitoring time.
to 3-2
Sequence Attributes (Common to A
, Tfr, and Tfs)
Monitors the time from the receive wait status to the
reception of the first data (header) in the step of the
sequence.
This timer is set to 3 seconds in this protocol macro data.
Monitors the time from the reception of the first data to the
completion of the reception in the step of the sequence.
This timer is set to 3 seconds in this protocol macro data.
Monitors the time from the sending of the header to the
sending of the last data.
This timer is set to 3 seconds in this protocol macro data.
mmunications
for the sequence are shown
Explanation
9. Program
ll Steps) in
67