●Internal addresses
T
hese addresses are used to operate this program only.
Address
Data type
5000.01
BOOL
Local_PMCRExecuting
5000.04
BOOL
Local_PMCRNormalE
500
0.05
BOOL
Local_PMCRErr
500 .06
0
BOOL
Local_DestinationDeviceError
5
000.07
BOOL
Local_PMCRErrorCode
5
010
UINT
L
ocal_ControlWord1
5
011
UINT
Local_ControlWord2
5
012
UIN
T
Local_P
5020
U
INT
Local_FirstSendWord
5500
UINT
Local_FirstReceiveWord
5501
UINT
Local_ReceiveSymbolArea_Res
ponseCode
Symbol name
nd
orEnd
MCR_ErrorCod
e
Explanation
Indicates the PMCR instruction execution status.
This flag turns ON when the
being execu
ted, and turns OFF when the PMCR
instruction is not executed.
Turns ON when the PMCR instruction ends normally.
Turns ON when a communications error (e.g.,
transmission error) occurs.
Turns ON when a destination device error occurs.
Turns ON when any of the following PMCR instruction
errors occurs.
(1) Sequen
ce No. error
(2) Data read/write area exceeded error
(3) Protocol macro syntax error
Execution parameter of PMCR instruction.
Execution parameter of
PMCR instruction.
Stores the error cod
e when a PM
occurs.
Sets the number of send message words of
PMCR instruction.
Stores
the number of message words received from
the destination device.
Stores the error code of a
destination device when a
destination device error occ
9. Program
PMCR instruction is
CR instruction error
the
urs.