Grid connect photovoltaic inverter
Hide thumbs Also See for KP100G:
Table of Contents

Advertisement

KP100G
RS-232C
If the RS-485 card is inserted, RS-232C is not available. To use RS-232C interface, remove RS-485 card.
The RS-232C interface has a protection cover, which can be unbolted and removed with a screwdriver as shown in Fig, 5-31 and. Fig, 5-32.
Fig, 5-31 RS-232C interface
KP100G uses a DB9 socket for the RS-232C interface. Remove the DB9 socket cover before use. The pin assignment of this DB9 socket is listed
In.Table 5-2.
Table 5-2 Pin assignment
Pin
Signal Assignment
1
N.C.
2
TxD
3
RxD
4
N.C.
5
Common
6
N.C.
7
N.C.
8
N.C.
9
N.C.
N.C. means "No Connection
Remove
these screws
Fig, 5-32 Socket available for RS-232C connection
5 4 3 2 1
9 8 7 6
Fig, 5-33 Female connector
27
Female
Side